On Junos devices with the BGP graceful restart helper mode enabled or the BGP graceful restart mechanism enabled, a certain sequence of BGP session restart on a remote peer that has the graceful restart mechanism enabled may cause the local routing protocol daemon (RPD) process to crash and restart. Repeated crashes of the RPD process can cause prolonged Denial of Service (DoS). Graceful restart helper mode for BGP is enabled by default. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S3; 16.2 versions prior to 16.2R2-S9; 17.1 versions prior to 17.1R3; 17.2 versions prior to 17.2R3; 17.2X75 versions prior to 17.2X75-D105; 17.3 versions prior to 17.3R3-S2; 17.4 versions prior to 17.4R1-S7, 17.4R2-S2, 17.4R3; 18.1 versions prior to 18.1R3-S2; 18.2 versions prior to 18.2R2; 18.2X75 versions prior to 18.2X75-D12, 18.2X75-D30; 18.3 versions prior to 18.3R1-S4, 18.3R2. Junos OS releases prior to 16.1R1 are not affected.
With Rapid7 live dashboards, I have a clear view of all the assets on my network, which ones can be exploited, and what I need to do in order to reduce the risk in my environment in real-time. No other tool gives us that kind of value and insight.
– Scott Cheney, Manager of Information Security, Sierra View Medical Center