Rapid7 Vulnerability & Exploit Database

Juniper Junos OS: 2021-04 Security Bulletin: Junos OS: MX Series with MS-PIC, MS-SPC3, MS-MIC or MS-MPC: The BRAS Subscriber Services service activation portal is vulnerable to a Denial of Service (DoS) via malformed HTTP packets (JSA11144) (CVE-2021-0251)

Free InsightVM Trial No Credit Card Necessary
Watch Demo See how it all works
Back to Search

Juniper Junos OS: 2021-04 Security Bulletin: Junos OS: MX Series with MS-PIC, MS-SPC3, MS-MIC or MS-MPC: The BRAS Subscriber Services service activation portal is vulnerable to a Denial of Service (DoS) via malformed HTTP packets (JSA11144) (CVE-2021-0251)

Severity
5
CVSS
(AV:N/AC:L/Au:N/C:N/I:N/A:P)
Published
04/16/2021
Created
04/16/2021
Added
04/16/2021
Modified
03/21/2022

Description

A NULL Pointer Dereference vulnerability in the Captive Portal Content Delivery (CPCD) services daemon (cpcd) of Juniper Networks Junos OS on MX Series with MS-PIC, MS-SPC3, MS-MIC or MS-MPC allows an attacker to send malformed HTTP packets to the device thereby causing a Denial of Service (DoS), crashing the Multiservices PIC Management Daemon (mspmand) process thereby denying users the ability to login, while concurrently impacting other mspmand services and traffic through the device. Continued receipt and processing of these malformed packets will create a sustained Denial of Service (DoS) condition. While the Services PIC is restarting, all PIC services will be bypassed until the Services PIC completes its boot process. An attacker sending these malformed HTTP packets to the device who is not part of the Captive Portal experience is not able to exploit this issue. This issue is not applicable to MX RE-based CPCD platforms. This issue affects: Juniper Networks Junos OS on MX Series 17.3 version 17.3R1 and later versions prior to 17.4 versions 17.4R2-S9, 17.4R3-S2; 18.1 versions prior to 18.1R3-S9; 18.2 versions prior to 18.2R3-S3; 18.3 versions prior to 18.3R3-S1; 18.4 versions prior to 18.4R3; 19.1 versions prior to 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R2; 19.3 versions prior to 19.3R3. This issue does not affect: Juniper Networks Junos OS versions prior to 17.3R1.

Solution(s)

  • juniper-junos-os-upgrade-latest

With Rapid7 live dashboards, I have a clear view of all the assets on my network, which ones can be exploited, and what I need to do in order to reduce the risk in my environment in real-time. No other tool gives us that kind of value and insight.

– Scott Cheney, Manager of Information Security, Sierra View Medical Center

;