Rapid7 Vulnerability & Exploit Database

Juniper Junos OS: 2017-10 Security Bulletin: SRX Series: Embedded ICMP may cause the flowd process to crash (JSA10813) (CVE-2017-10610)

Free InsightVM Trial No Credit Card Necessary
Watch Demo See how it all works
Back to Search

Juniper Junos OS: 2017-10 Security Bulletin: SRX Series: Embedded ICMP may cause the flowd process to crash (JSA10813) (CVE-2017-10610)

Severity
4
CVSS
(AV:N/AC:M/Au:N/C:N/I:N/A:P)
Published
10/12/2017
Created
07/25/2018
Added
10/12/2017
Modified
03/21/2022

Description

On SRX Series devices, a crafted ICMP packet embedded within a NAT64 IPv6 to IPv4 tunnel may cause the flowd process to crash. Repeated crashes of the flowd process constitutes an extended denial of service condition for the SRX Series device. This issue only occurs if NAT64 is configured. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D71, 12.3X48 prior to 12.3X48-D55, 15.1X49 prior to 15.1X49-D100 on SRX Series. No other Juniper Networks products or platforms are affected by this issue.

Solution(s)

  • juniper-junos-os-upgrade-latest

With Rapid7 live dashboards, I have a clear view of all the assets on my network, which ones can be exploited, and what I need to do in order to reduce the risk in my environment in real-time. No other tool gives us that kind of value and insight.