ProSoft Technology ICX35 devices (X35-HWC-A and ICX35-HWC-E) contain a login lockout bypass in the integrated module web page. The account lockout mechanism that restricts repeated failed authentication attempts is enforced in client-side JavaScript, so a remote attacker can reset the lockout and continue submitting password guesses by deleting the relevant browser cookies, defeating the brute-force protection. This vulnerability has been addressed in version 1.14.158.
CVSS Details
- CVSS 4.0 Base Score: 8.2 (HIGH)
- CVSS 4.0 Vector: (CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X)
- CVSS 3.1 Base Score: 5.9
- CVSS 3.1 Vector: (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N)