The SibRaRecoverableSiXaResource class in the Default Messaging Component in IBM WebSphere Application Server (WAS) 6.1 before 6.1.0.41 does not properly handle a Service Integration Bus (SIB) dump operation involving the First Failure Data Capture (FFDC) introspection code, which allows local users to obtain sensitive information by reading the FFDC log file.
| Product | Vendor Advisory | Solution File | Added | Published |
|---|---|---|---|---|
| Ibm Was | — | Upgrade to minimal fix pack levels as required by interim fixes and then apply latest Interim Fix. | Apr 27, 2018 | Jan 15, 2012 |