FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system.
CVSS Details
- CVSS 4.0 Base Score: 9.3 (CRITICAL)
- CVSS 4.0 Vector: (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X)
- CVSS 3.1 Base Score: 7.5
- CVSS 3.1 Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N)