When a device running Juniper Networks Junos OS with MPC7, MPC8, or MPC9 line cards installed and the system is configured for inline IP reassembly, used by L2TP, MAP-E, GRE, and IPIP, the packet forwarding engine (PFE) will become disabled upon receipt of small fragments requiring reassembly, generating the following error messages: [LOG: Err] MQSS(2): WO: Packet Error - Error Packets 1, Connection 29 [LOG: Err] eachip_hmcif_rx_intr_handler(7259): EA[2:0]: HMCIF Rx: Injected checksum error detected on WO response - Chunk Address 0x0 [LOG: Err] MQSS(2): DRD: RORD1: CMD reorder ID error - Command 11, Reorder ID 1960, QID 0 [LOG: Err] MQSS(2): DRD: UNROLL0: HMC chunk address error in stage 5 - Chunk Address: 0xc38fb1 [LOG: Notice] Error: /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc), scope: pfe, category: functional, severity: major, module: MQSS(2), type: DRD_RORD_ENG_INT: CMD FSM State Error [LOG: Notice] Performing action cmalarm for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major [LOG: Notice] Performing action get-state for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major [LOG: Notice] Performing action disable-pfe for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major By continuously sending fragmented packets that cannot be reassembled, an attacker can repeatedly disable the PFE causing a sustained Denial of Service (DoS). This issue affects Juniper Networks Junos OS: 17.2 versions prior to 17.2R3-S4 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S9, 17.4R3-S1 on MX Series; 18.1 versions prior to 18.1R3-S10 on MX Series; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D34, 18.2X75-D41, 18.2X75-D53, 18.2X75-D65, 18.2X75-D430 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S2 on MX Series; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3 on MX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series; 19.3 versions prior to 19.3R2-S2, 19.3R3 on MX Series. This issue is specific to inline IP reassembly, introduced in Junos OS 17.2. Versions of Junos OS prior to 17.2 are unaffected by this vulnerability.
With Rapid7 live dashboards, I have a clear view of all the assets on my network, which ones can be exploited, and what I need to do in order to reduce the risk in my environment in real-time. No other tool gives us that kind of value and insight.
– Scott Cheney, Manager of Information Security, Sierra View Medical Center